Expanding on the enhancements added during the COVID-19 restrictions, the Young Calibration Laboratory (Lab 0604) has invested a further £200,000 in reference instrumentation for the calibration of temperature and humidity sensors. Having successfully extended the UKAS scope of accreditation in the previous year, the company has further invested in both dry block and stirred liquid bath calibration systems, along with a range Fluke SPRT’s which will see continued improvements to the available CMC measurement uncertainty. Customers can expect to see improved turnaround times and extended capabilities for all temperature probes, loggers and bath calibrations in the -40 to 200°C temperature range over the coming months.
ISO 17025 Temperature Calibration within the laboratory covers the calibration of thermocouples, thermistors and platinum resistance probes using a range of leading manufacturer stirred liquid baths and SPRTs across a temperature range of -40 to 200°C with a CMC from ± 0.05°C. The reference SPRT’s provide a comparative measurement technique whilst held in stable isothermal states for optimum calibration periods offering cost effective calibrations.
Dry or air probe calibrations for system temperature measurements in HVAC probes, anemometers, IAQ sensors, data loggers, RH probes and weather stations can also be calibrated within a controlled environmental chamber across a 0 to 60°C range with a CMC from ± 0.19°C. For the user undertaking their own internal calibration work the laboratory is accredited for the calibration of dry block calibrators and stirred liquid baths using single and multipoint time dependent temperature profiling, also referred to as spatial temperature surveying or mapping with a CMC from ± 0.045°C.
UKAS ISO 17025 Humidity Calibration Services
Complimenting the Temperature Calibration Laboratory is another of the company’s latest investments for its’ UKAS accredited relative humidity and dew point calibration services. The UKAS (Lab 0604) schedule now covers dew point calibration from -32 to 60°C, relative humidity calibration from 5 to 95% and all across a temperature range of 0 to 60°C. Utilising both controlled environment chambers with reference SPRT’s, chilled mirrors and comparative RH probes, the facility can achieve a Relative Humidity uncertainty CMC of ± 0.2% to 1.9% across the full temperature range of 0-60°C whilst achieving a ± 0.31°C CMC for dew point measurement.
Contact Details
Young Calibration Ltd
5 Cecil Pashley Way, Shoreham by Sea, West Sussex, BN43 5FF
United Kingdom
Tel: +44 (0)1273 455572
Email: [email protected]